LMR-400

LMR-400

Flexible Low Loss Communications Coax
Ideal for…

• Drop-in replacement for RG-8/9913 Air-Dielectric type Cable
• Jumper Assemblies in Wireless Communications Systems
• Short Antenna Feeder runs
• Any application (e.g. WLL, GPS, LMR) requiring an easily
routed, low loss RF cable

LMR® standard is a UV Resistant Polyethylene jacketed cable designed for 20-year service outdoor use. The bending and handling characteristics are significantly better than air-dielectric and corrugated hard-line cables.
LMR®- DB is identical to standard LMR plus has the advantage of being watertight. The addition of waterproofing compound in and around the foil/braid insures continuous reliable service should the jacket be inadvertently damaged during installation or in the future.
LMR®- FR is a non-halogen (non-toxic), low smoke, fire retardant cable designed for in-building runs that can be routed anywhere except air handling plenums. LMRFR has a UL/NEC & CSA rating of ‘CMR/MPR’ and ‘FT4’ respectively.
LMR®- FR-PVC is a general-purpose indoor cable and has a UL/NEC & CSA rating of ‘CMR/MPR’ and ‘FT4’ respectively. It is less expensive than LMR-FR, however it emits toxic fumes (HCL) and greater smoke density when burned.

LMR®- PVC is designed for low loss general-purpose indoor/outdoor applications and is somewhat more flexible than the standard polyethylene jacketed LMR.
LMR®- PVC-W is a white-jacketed version of LMRPVC for marine and other indoor/outdoor applications where color compatibility is desired.
Flexibility and bendability are hallmarks of the LMR- 400 cable design. The flexible outer conductor enables the tightest bend radius available for any cable of similar size and performance.
Low Loss is another hallmark feature of LMR-400. Size for size LMR has the lowest loss of any flexible cable and comparable loss to semirigid hard-line cables.

RF Shielding is 50 dB greater than typical single shielded coax (40 dB). The multi-ply bonded foil outer conductor is rated conservatively at > 90 dB (i.e. >180 dB between two adjacent cables).
Weatherability: LMR-400 cables designed for outdoor exposure incorporate the best materials for UV resistance and have life expectancy in excess of 20 years.
Connectors: A wide variety of connectors are available for LMR-400 cable, including all common interface types, reverse polarity, and a choice of solder or non-solder center pins. Most LMR connectors employ crimp outer attachment using standard hex crimp sizes.
Cable Assemblies: All LMR-400 cable types are available as pre-terminated cable assemblies. Refer to the section on FlexTech for further details.

Part Description Stock
Color
Part No. Application Jacket Color
LMR-400 Outdoor PE Black 54001
LMR-400-DB Outdoor/Watertight PE Black 54091
LMR-400-FR Indoor -Riser CMR FRPE Black 54030
LMR-400-FR-PVC Indoor -Riser CMR FRPVC Black 54073
LMR-400-PVC Indoor/Outdoor PVC Black 54218
LMR-400-PVC-W Indoor/Outdoor PVC White 54204
Construction Specifications
Description Material In. (mm)
Inner Conductor Solid BCCAI 0.108 (2.74)
Dielectric Foam PE 0.285 (7.24)
Outer Conductor Aluminum Tape 0.291 (7.39)
Overall Braid Tinned Copper 0.320 (8.13)
Jacket (see table above) 0.405 (10.29)

 

Mechanical Specifications
Performance Property Units US (metric)
Bend Radius: installation in. (mm) 1.00 (25.4)
Bend Radius: repeated in. (mm) 4.0 (101.6)
Bending Moment ft-lb (N-m) 0.5 (0.68)
Weight lb/ft (kg/m) 0.068 (0.10)
Tensile Strength lb (kg) 160 (72.6)
Flat Plate Crush lb/in. (kg/mm) 40 (0.71)
Environmental Specifications
Performance Property oF oC
Installation Temperature Range -40/+185 -40/+85
Storage Temperature Range -94/+185 -70/+85
Operating Temperature Range -40/+185 -40/+85

 

Electrical Specifications
Performance Property Units US   (metric)
Cutoff Frequency GHz   16.2  
Velocity of Propagation %   85  
Dielectric Constant NA   1.38  
Time Delay nS/ft (nS/m) 1.20   (3.92)
Impedance ohms   50  
Capacitance pF/ft (pF/m) 23.9   (78.4)
Inductance uH/ft (uH/m) 0.060   (0.20)
Shielding Effectiveness dB   >90  
DC Resistance
Inner Conductor ohms/1000ft (/km) 1.39   (4.6)
Outer Conductor ohms/1000ft (/km) 1.65   (5.4)
Voltage Withstand Volts DC   2500  
Jacket Spark Volts RMS   8000  
Peak Power kW   16  
Attenuation vs. Frequency (typical)
Frequency (MHz) 30 50 150 220 450 900 1500 1800 2000 2500 5800
Attenuation dB/100 ft 0.7 0.9 1.5 1.9 2.7 3.9 5.1 5.7 6.0 6.8 10.8
Attenuation dB/100 m 2.2 2.9 5.0 6.1 8.9 12.8 16.8 18.6 19.6 22.2 35.5
Avg. Power kW 3.33 2.57 1.47 1.20 0.83 0.58 0.44 0.40 0.37 0.33 0.21