LMR-400
Flexible Low Loss Communications Coax
Ideal for…
• Drop-in replacement for RG-8/9913 Air-Dielectric type Cable
• Jumper Assemblies in Wireless Communications Systems
• Short Antenna Feeder runs
• Any application (e.g. WLL, GPS, LMR) requiring an easily
routed, low loss RF cable
|
|
• LMR® standard is a UV Resistant Polyethylene jacketed cable designed for 20-year service outdoor use. The bending and handling characteristics are significantly better than air-dielectric and corrugated hard-line cables.
• LMR®- DB is identical to standard LMR plus has the advantage of being watertight. The addition of waterproofing compound in and around the foil/braid insures continuous reliable service should the jacket be inadvertently damaged during installation or in the future.
• LMR®- FR is a non-halogen (non-toxic), low smoke, fire retardant cable designed for in-building runs that can be routed anywhere except air handling plenums. LMRFR has a UL/NEC & CSA rating of ‘CMR/MPR’ and ‘FT4’ respectively.
• LMR®- FR-PVC is a general-purpose indoor cable and has a UL/NEC & CSA rating of ‘CMR/MPR’ and ‘FT4’ respectively. It is less expensive than LMR-FR, however it emits toxic fumes (HCL) and greater smoke density when burned.
• LMR®- PVC is designed for low loss general-purpose indoor/outdoor applications and is somewhat more flexible than the standard polyethylene jacketed LMR.
• LMR®- PVC-W is a white-jacketed version of LMRPVC for marine and other indoor/outdoor applications where color compatibility is desired.
• Flexibility and bendability are hallmarks of the LMR- 400 cable design. The flexible outer conductor enables the tightest bend radius available for any cable of similar size and performance.
• Low Loss is another hallmark feature of LMR-400. Size for size LMR has the lowest loss of any flexible cable and comparable loss to semirigid hard-line cables.
|
• RF Shielding is 50 dB greater than typical single shielded coax (40 dB). The multi-ply bonded foil outer conductor is rated conservatively at > 90 dB (i.e. >180 dB between two adjacent cables).
• Weatherability: LMR-400 cables designed for outdoor exposure incorporate the best materials for UV resistance and have life expectancy in excess of 20 years.
• Connectors: A wide variety of connectors are available for LMR-400 cable, including all common interface types, reverse polarity, and a choice of solder or non-solder center pins. Most LMR connectors employ crimp outer attachment using standard hex crimp sizes.
• Cable Assemblies: All LMR-400 cable types are available as pre-terminated cable assemblies. Refer to the section on FlexTech for further details.
Part Description |
Stock
Color |
Part No. |
Application |
Jacket |
Color |
LMR-400 |
Outdoor |
PE |
Black |
54001 |
LMR-400-DB |
Outdoor/Watertight |
PE |
Black |
54091 |
LMR-400-FR |
Indoor -Riser CMR |
FRPE |
Black |
54030 |
LMR-400-FR-PVC |
Indoor -Riser CMR |
FRPVC |
Black |
54073 |
LMR-400-PVC |
Indoor/Outdoor |
PVC |
Black |
54218 |
LMR-400-PVC-W |
Indoor/Outdoor |
PVC |
White |
54204 |
Construction Specifications |
Description |
Material |
In. |
(mm) |
Inner Conductor |
Solid BCCAI |
0.108 |
(2.74) |
Dielectric |
Foam PE |
0.285 |
(7.24) |
Outer Conductor |
Aluminum Tape |
0.291 |
(7.39) |
Overall Braid |
Tinned Copper |
0.320 |
(8.13) |
Jacket |
(see table above) |
0.405 |
(10.29) |
|
Mechanical Specifications |
Performance Property |
Units |
US |
(metric) |
Bend Radius: installation |
in. (mm) |
1.00 |
(25.4) |
Bend Radius: repeated |
in. (mm) |
4.0 |
(101.6) |
Bending Moment |
ft-lb (N-m) |
0.5 |
(0.68) |
Weight |
lb/ft (kg/m) |
0.068 |
(0.10) |
Tensile Strength |
lb (kg) |
160 |
(72.6) |
Flat Plate Crush |
lb/in. (kg/mm) |
40 |
(0.71) |
Environmental Specifications |
Performance Property |
oF |
oC |
Installation Temperature Range |
-40/+185 |
-40/+85 |
Storage Temperature Range |
-94/+185 |
-70/+85 |
Operating Temperature Range |
-40/+185 |
-40/+85 |
|
Electrical Specifications |
Performance Property |
Units |
US |
|
(metric) |
Cutoff Frequency |
GHz |
|
16.2 |
|
Velocity of Propagation |
% |
|
85 |
|
Dielectric Constant |
NA |
|
1.38 |
|
Time Delay |
nS/ft (nS/m) |
1.20 |
|
(3.92) |
Impedance |
ohms |
|
50 |
|
Capacitance |
pF/ft (pF/m) |
23.9 |
|
(78.4) |
Inductance |
uH/ft (uH/m) |
0.060 |
|
(0.20) |
Shielding Effectiveness |
dB |
|
>90 |
|
DC Resistance |
Inner Conductor |
ohms/1000ft (/km) |
1.39 |
|
(4.6) |
Outer Conductor |
ohms/1000ft (/km) |
1.65 |
|
(5.4) |
Voltage Withstand |
Volts DC |
|
2500 |
|
Jacket Spark |
Volts RMS |
|
8000 |
|
Peak Power |
kW |
|
16 |
|
|